STUDIO APARTMENT Stainless steel gas hob & Cooker hood Electrical induction hob & Cooker hod CITYGAS ROAD AND CARPARK WORK Asphaltic hotmix concrete of W3B, laid in one layer to approved grade and level, compacting with suitable rollers including power saw cutting of the edges, spraying of tack coat, all necessary sweeping and disposal of the excavated material all as directed by the S.O. AERATION SLABS, ETC. Page 50 Generated on 08/10/2019 HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATE FOR Building Tradesmen & Repair Works (202001) S/N DESCRIPTION UNIT RATE($) Code 0890 Supply and fix (in replacement) top and bottom kitchen cabinet in laminate finish complete with doors & door with clear glass, drawers, adjustable shelves including movable cabinets with drawer below complete with solid surface worktop with upturn edge etc, all in accordance to Technical Specifications and Guide Drawings for Studio Apartments. M 1495.00 TZ384 0891 Supply and fix (in replacement) Wardrobe in laminate finish complete with sliding doors, drawers, adjustable shelves, full height clear mirror, aluminium hanging rod and full height metal handle etc, all in accordance to Technical Specifications and Guide Drawings for Studio Apartments Type A & B. M 1265.00 TZ385 0892 Built-in Stainless Steel Gas Hob fitted with three Gas Burner and one with a double ring burner; flame failure safety valve; electric automatic ignition; pan support; nozzle fitted for town gas supply including all connection and sealant as specified. (In Replacement) NO. 259.60 TZ386 0893 Cassette-type Cooker Hood of the same make to match the existing Gas Hob as specified. (In Replacement) NO. 182.60 TZ387 0894 Built-in two-zone electrical induction hob, in compliance with Safety Authority requirements with Safety Mark certification; including all connection and sealant as specified. (In Replacement) NO. 360.80 TSN333 0895 Cassette-type Cooker Hood of the same make to match the existing electrical induction hob as specified. (In Replacement) NO. 225.10 TSN334 0896 To engage Citygas to remove and reinstall Gas pipes JOB 517.50 TCL207 0897 To engage Citygas to replace Gas Water Heater JOB 193.45 TCL209 0898 To engage Citygas to tightened lossen gas pipe after the meter JOB 80.50 TCL210 0899 25mm consolidated thickness M2 6.00 TL005 0900 50mm consolidated thickness M2 10.00 TL006 0901 600 x 600 x 75mm thick precast concrete aeration slab reinforced with T9mm diameter steel bars on 40mm thick granite fines to carpark or tree planting area including topping up all voids with approved soil mixture and close turf with cow grass. NO. 20.20 TL023 0902 100mm thick Grade 30 cast-in-situ concrete paving slab reinforced with WSF A10 reinforcement with patterned voids at 200mm centre to centre formed by expanded polystyrene formers as carparks lots, on 40mm thick granite fines including necessary formwork and providing approved soil mixture to voids and close turf with cow grass as shown in drawings. M2 50.00 OT1650
Precast Concrete Kerb of the following size to details shown in drawing and jointing in cement mortar(1:3) Precast concrete divider kerb specially cast solid including cement and sand mortar (1:3) all as detailed on the drawings Type W3B premix hump all as detailed on the drawings Page 51 Generated on 08/10/2019 HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATE FOR Building Tradesmen & Repair Works (202001) S/N DESCRIPTION UNIT RATE($) Code 0903 100mm x 150mm M 10.70 TSN335 0904 100 x 225mm. M 12.70 TL010 0905 100 x 300mm. M 16.20 TL011 0906 100mm x 450mm M 20.30 TSN336 0907 125mm x 175mm M 13.50 TSN337 0908 125 x 225mm. M 15.20 TL013 0909 125 x 300mm. M 17.80 TL015 0910 150mm x 135mm M 14.00 TSN338 0911 150mm x 260mm M 19.10 TSN339 0912 300 x 150mm. M 24.30 TL016 0913 300 x 180mm. M 27.00 TL017 0914 380mm x 200mm M 29.00 TSN340 0915 450 x 225mm. M 40.70 TL020 0916 225 x 150 x 150mm precast concrete road lane divider with 2 nos of 51mm diameter reflector disc secured to concrete surface and including painting, concrete foundation and excavation. NO. 30.50 TZ023 0917 1800mm wide M 100.00 TL007a 0918 4000mm wide M 160.00 TL007b 0919 5800mm wide raised zebra crossing with Type "W3B" premix including painting as shown in Drawings M 308.60 TL007c 0920 225 x 112.5 x 80mm thick coloured interlocking concrete paving blocks for forming raised hump at linkway service roads to approved pattern comprising of plant mixed crushed granite aggregate including 50mm thick compacted sand bed, filling all joints with joint-filling sand and removal & disposal of existing paving blocks etc. M2 60.40 TL009a 0921 225 x 112.5 x 80mm thick coloured interlocking concrete paving blocks for forming 1800mm wide road hump across interlocking paving driveways to approved pattern comprising of plant mixed crushed granite aggregate including 50mm thick compacted sand bed, filling all joints with joint-filling sand and removal & disposal of existing paving blocks etc. M 108.80 TL009b 0922 Rubber section of approximately 500x420x50mm height mounted onto road surface to form a speed hump in alternate black and yellow colour tone complete with built-in glass reflectors including all necessary mounting hardware in accordance with manufacturer's directions. NO. 114.90 TZ382
Created with BuildVu